27024

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 stop A triggered

%1 = Axis number This alarm follows an

Alarm 27011 "Safe velocity exceeded" (when configured as such in $MA_SAFE_VELO_STOP_MODE, $MA_SAFE_VELO_STOP_REACTION)

Alarm 27013 "Safe braking ramp exceeded",

Alarm 27023 "Stop B triggered" unsuccessful test stop.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Trigger a "Pulse suppression".

Eliminate causes of

alarm "Save velocity exceeded", alarm "Safe braking ramp exceeded", alarm "Stop B triggered" unsuccessful test stop (see description of these alarms).

Switch control OFF - ON.


1-1205


© Siemens AG 2005 All Rights Reserved