27203 |
PROFIsafe: MD %1[%2]: SPL assignment error |
Parameters: |
%1 = MD name |
Definitions: |
%2 = MD array index The parameterization of the specified machine data for the link between the SPL interface and a PROFIsafe module is incorrect because of the following reasons: Exchanged bit limits (upper bit value < lower bit value) Bit values greater than definition of SPL interface (bit value > 64) Number of bits too high for this PROFIsafe module (upper bit value - lower bit value + 1 > 8) No SPL assignment parameterized (both bit values equal to zero) Incorrect SPL assignment (bit value equals zero) |
Reactions: |
- Mode group not ready. - Channel not ready. - NC Start disable in this channel. |
Remedy: Program Continuation: |
- Interface signals are set. - Alarm display. - NC Stop on alarm. Correct the MD. Switch control OFF - ON. |