27254

Parameters:


Definitions:


Reactions:


Remedy:

Program Continuation:


PROFIsafe: F module %1, error on channel %2; %3<ALSI>

%1 = PROFIsafe address

%2 = Channel type, channel number

%3 = System variable array index extension

The F module signals that an error occurred in the interface of the specified channel. This alarm is only triggered for ET200S F modules.

The type of channel (input or output channel) is indicated by the abbreviations IN and OUT in %2.

A specific alarm message can be programmed for each of the system variables on the HMI via parameter %3:

%3 = 1....64: Error in system variables $A_INSE[1...64]

%3 = 65...128: Error in system variables $A_OUTSE[1...64]

%3 = -1: Error in an input or output channel for which there is no SPL assignment

-    Mode group not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Trigger a STOP D/E (settable via MD $MN_SPL_STOP_MODE) on all axes with safety functionality.

Check wiring. Wiring OK: replace F module.

Clear alarm with the RESET key. Restart part program


1-1263


© Siemens AG 2005 All Rights Reserved