61115

Channel %1 Block %2: Approach or retract mode(straight / circle / plane / space) incorrectly defined

Parameters:

%1 = Channel number

%2 = Block number, label

Definitions:

The approach or retract mode to/from the contour has been incorrectly defined. Alarm triggered by following cycle: CYCLE72.

Reactions:

-    Alarm display.

-    Interface signals are set.

-    NC Start disable in this channel.

Remedy:

Program Continuation:

- Interpreter stop

Check parameter _AS1 or _AS2.

Clear alarm with the RESET key. Restart part program

© Siemens AG 2005 All Rights Reserved