61115 |
Channel %1 Block %2: Approach or retract mode(straight / circle / plane / space) incorrectly defined |
Parameters: |
%1 = Channel number %2 = Block number, label |
Definitions: |
The approach or retract mode to/from the contour has been incorrectly defined. Alarm triggered by following cycle: CYCLE72. |
Reactions: |
- Alarm display. - Interface signals are set. - NC Start disable in this channel. |
Remedy: Program Continuation: |
- Interpreter stop Check parameter _AS1 or _AS2. Clear alarm with the RESET key. Restart part program |
© Siemens AG 2005 All Rights Reserved