Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Channel %1 block %2: Wrong definition of tapping axis transformation ratio (machine data)
%1 = Channel number %2 = Block number, label
Alarm triggered by following cycles: CYCLE84, CYCLE840.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
Check machine data 31050 and 31060 in the appropriate gear stage of the drilling axis. Clear alarm with the RESET key. Restart part program
© Siemens AG 2005 All Rights Reserved