61602

Parameters:

Definitions:

Remedy:

Channel %1 block %2: Tool width incorrectly defined

%1 = Channel number %2 = Block number, label

Plunge cutter is larger than the programmed groove width. Alarm triggered by following cycle: CYCLE93.

Check tool or change program.

1-1546