111106

Definitions:


Reactions:


Remedy:


Program Continuation:


No spindle stop for a block change

The displayed spindle has been programmed as spindle or as axis even though a positioning operation is still running from the previous block (with SPOSA ... spindle positioning beyond block limits).

Example:

N100 SPOSA [2] = 100 etc.,

N126 S2 = 1000 M2 = 04 Error, if the spindle S2is still running from block N100!

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Before programming the spindle/axis again using the SPOSA instruction, a WAITS command should be activated in order to wait for the programmed spindle position. Example:

N100 SPOSA [2] = 100 etc.,

N125 WAITS (2)

N126 S2 = 1000 M2 = 04

Clear alarm with the RESET key. Restart part program


1-2321


© Siemens AG 2005 All Rights Reserved