300009

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 measuring circuit %3 wrong measuring circuit type (type %4 used)

%1 = NC axis number %2 = Drive number %3 = Measuring circuit number %4 = Measuring circuit type

The available, displayed actual value module on the drive FBG cannot process the signal type that was stated via the axis-specific machine data 30240 ENC_TYPE [e]=S (e ... encoder index - the position control works with this encoder, E ... , S ... signal type of the actual value encoder - 0 ... simulation axis without hardware, 1 ... raw encoder signals, 2 ... rectangle signals).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department.

Set MD 30240 ENC_TYPE [e] to 1 (0 should only be entered for pure simulation axes which are to travel in the actual-value display only).

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved


1-2528