300500

Parameters:


Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 system error, error codes %3, %4

%1 = NC axis number %2 = Drive number %3 = Error code 1 %4 = Error code 2

The drive has signaled a system error.

Safety Integrated:

Request: In the corresponding cycle.

On FDD: Generator stop (corresponds to STOP B)

On MSD: Pulse and servo disable (corresponds to STOP A)

The error occurs if the computation time of the drive processor is not sufficient for the cycle indicated in the additional information.

Error no.: 03, additional information: 40, monitoring cycle too small for SINUMERIK Safety Integrated.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Notes on the error codes can be found under Section "Error codes of alarm 300500" in the SINUMERIK 840D/840Di/810D Diagnostics Guide.

NCK reset (POWER ON)

Safety Integrated: Increase the corresponding cycle or the cascade cycle (e.g. current, speed, position control cycle) or deselect the functions which are not required Any further search for the precise cause of error can only be performed by the development team. The displayed error codes are always needed for this. Reinitialization of the drive required.

Please inform the authorized personnel/service department. System Support, SIEMENS A&D MC, Hotline (Tel.: see alarm 1000).

Switch control OFF - ON.


1-2551