300714

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 power section code invalid

%1 = NC axis number %2 = Drive number

The code number of the power section entered in drive MD 1106: $MD_INVERTER_CODE (power section code number) does not match the power section in the drive configuration display (MD 13020: $MC_DRIVE_INVERTER_CODE).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Please inform the authorized personnel/service department. Delete modified machine data (e.g. controller data). Reset the drive (delete the bootfile) and repeat the startup. Switch control OFF - ON.


1-2593


© Siemens AG 2005 All Rights Reserved