Remedy:
Program Continuation:
Axis %1 drive %2 number of pole pairs invalid
%1 = NC axis number %2 = Drive number
FDD: The configured number of pole pairs in the drive MD 1112: $MD_NUM_POLE_PAIRS is outside the permissible range limits.
MSD: Modify MD 1134: $MD_MOTOR_NOMINAL_FREQUENCY (rated motor frequency) or MD 1400: $MD_MOTOR_RATED_SPEED (rated motor speed) is not correct.
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct MD 1112: $MD_NUM_POLE_PAIRS (number of motor pole pairs).
Switch control OFF - ON.
© Siemens AG 2005 All Rights Reserved