Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 safety monitoring checksum invalid, confirmation and acceptance test required!
%1 = NC axis number %2 = Drive number
The actual checksum of the safety-relevant MDs calculated by the drive and stored in MD 1398: $MD_SAFE_ACT_CHECKSUM (display of the checksum of the machine data for safe functions) has another value than the setpoint checksum stored during the last machine acceptance in MD 1399: $MD_SAFE_DES_CHECKSUM (checksum of the machine data for safe functions). The safety-relevant data have been modified or there is an error.
Request: During boot-up of the control.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Check, and if necessary, correct all safety-relevant MDs. Then perform POWER ON. Perform acceptance test.
Switch control OFF - ON.
© Siemens AG 2005 All Rights Reserved