300759

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 generator mode: response voltage > monitoring threshold

%1 = NC axis number %2 = Drive number

The value in MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) is greater than MD1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link monitoring).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department.

Modify drive machine data

Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or

Modify MD 1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link monitoring).

Clear alarm with the RESET key in all channels. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-2638