Remedy:
Program Continuation:
Axis %1 drive %2 generator mode: emergency retraction speed > max. motor speed
%1 = NC axis number %2 = Drive number
The value entered for the emergency retraction speed in MD1639: $MD_RETRACT_SPEED (emergency retraction speed) is greater than MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Please inform the authorized personnel/service department.
Modify drive machine data
Modify MD 1639: $MD_RETRACT_SPEED (emergency retraction speed) or Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed). Clear alarm with the RESET key in all channels. Restart part program.
© Siemens AG 2005 All Rights Reserved