300771

Parameters:

Definitions:

Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 asynchronous mode: converter frequency invalid

%1 = NC axis number %2 = Drive number

Only a converter frequency of 4 kHz or 8 kHz is permitted in asynchronous mode (selected by MD 1465 < MD 1146).

Modify MD 1465: $MD_SWITCH_SPEED_MSD_AM (switchover speed MSD/AM) Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed) The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. Modify MD 1100: $MD_PWM_FREQUENCY (pulse width modulation frequency) or deselect AM mode (make the value in MD 1465: $MD_SWITCH_SPEED_MSD_AM less than the value in MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED.

Clear alarm with the RESET key in all channels. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-2652