300799

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 data backup and reboot required

%1 = NC axis number %2 = Drive number

Since drive machine data have been changed, it is necessary to recalculate parameters. This is initiated by pressing the softkey CALCULATE. After calculating the control parameters, it is necessary to save the machine data and to reboot.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

The newly calculated data must be saved (Softkey: SAVE). The new parameters will become effective during the next boot procedure!

Switch control OFF - ON.


© Siemens AG 2005 All Rights Reserved