300875 |
Axis %1 drive %2 fixed link voltage of axes differ |
Parameters: |
%1 = NC axis number %2 = Drive number |
Definitions: |
An unequal fixed voltage MD1161: $MD_FIXED_LINK_VOLTAGE (DC link fixed voltage) has been found for axes of a drive module. Since a fixed voltage <> 0 replaces the measured DC link voltage value, but the DC link voltage value is measured only once for all axes of a drive module, the fixed voltage must be identical on all module axes before it is accepted. |
Reactions: |
- Interface signals are set. - Alarm display. |
Remedy: |
Please inform the authorized personnel/service department. Set the same fixed voltage (MD 1161) on all module axes. |
Program Continuation: |
Alarm display showing cause of alarm disappears. No further operator action necessary. |