300901

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 stop B triggered

%1 = Axis number %2 = Drive number

The drive is disabled via STOP B. This blocks the pulses over the relay "AntriebJMP". Request: In monitoring cycle.

If STOP B has been triggered, this can have several reasons:

1.    Safe zero speed control has responded.

2.    Call after STOP F, that means an error has occurred during cross-comparison.

3.    "SG-specific stop reaction" is set to STOP B and has responded.

The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not ready).

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Please inform the authorized personnel/service department. The user must check the cause and initiate the corresponding measures.

Switch control OFF - ON.


1-2687


© Siemens AG 2005 All Rights Reserved