301713
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
Axis %1 drive %2 resolution SSI direct measuring system invalid
%1 = NC axis number %2 = Drive number
Configuration of the direct measuring system is faulty for SSI encoder: MD_1032 $MD_ENC_ABS_RESOL_DIRECT must not be 0.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Set MD_1032 $MD_ENC_ABS_RESOL_DIRECT to the correct value:
Rotary encoder: Singleturn resolution (increments per revolution).
Linear encoder: Resolution of an increment (in nanometers).
Switch control OFF - ON.
1-2711