301719

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 power section data incomplete

%1 = NC axis number %2 = Drive number

The data for the power section are incomplete:

Operation of a power section with an FDD motor requires: MD_1178 $MD_INVERTER_DERATING_SYN (derating factor at 8kHz)

Operation of a power section with an MSD motor requires: MD_1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)

Operation of a power section with a PE MSD motor requires: MD_1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)

MD_1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE MSD)

MD_1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE MSD).

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Carry out new start-up with power section selection or enter the following data: Operation of a power section with an FDD motor requires:

MD_1178 $MD_INVERTER_DERATING_SYN (derating factor at 8kHz)

Operation of a power section with an MSD motor requires:

MD_1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)

Operation of a power section with a PE MSD motor requires:

MD_1179 $MD_INVERTER_DERATING_ASYN (derating factor at 8kHz)

MD_1175 $MD_INVERTER_THERM_CURR_ASYN (limit current power section for PE MSD)

MD_1177 $MD_INVERTER_RATED_CURR_ASYN (limit current power section for PE MSD).

Switch control OFF - ON.


1-2717