310611

Axis %1 drive %2 pressure sensor failed

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

Power limitation or friction compensation is activated: Modify MD 5241: bit 0 or bit 1 is set and both actual pressure values are less than 2% of the system pressure in MD 5101: WORKING_PRESSURE on performance enable.

Cause: Pressure sensor or connecting cable defective.

Reactions:

-    Mode group not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

Check the connection of both pressure sensors.

If no pressure sensors are installed:

Deactivate the force limitation: Modify MD 5241: reset bit 0

Deactivate friction compensation: Modify MD 5241: reset bit 1

Program Continuation:

Clear alarm with the RESET key in all channels of this mode group. Restart part program.

© Siemens AG 2005 All Rights Reserved

1-2724