310706

Parameters:

Definitions:


Reactions:


Remedy:

Program Continuation:


Axis %1 drive %2 maximum working speed invalid

%1 = NC axis number %2 = Drive number

Because of the high maximum motor speed in the drive MD 5401: DRIVE_MAX_SPEED and the speed controller cycle in MD 5001: SPEEDCTRL_CYCLE_TIME sufficiently high speeds can occur to cause a format overflow.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Reduce the maximum working speed in MD 5401: DRIVE_MAX_SPEED or set a smaller speed controller cycle in MD 5001: SPEEDCTRL_CYCLE_TIME.

Switch control OFF - ON.


1-2731