310759

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 bandwidth numerator larger than double blocking frequency

%1 = NC axis number %2 = Drive number

The bandwidth numerator of a speed or manipulated variable setpoint filter is greater than twice the blocking frequency.

This error message is only issued for the general bandstop filter if:

Speed filter 1:

MD 5516 > 0.0 or MD 5520 <> 100.0 Manipulated variable filter 1:

MD 5212 > 0.0 Manipulated variable filter 2:

MD 5215 > 0.0

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

The bandwidth numerator must be less than twice the blocking frequency.

Speed filter 1:

BSP bandwidth numerator drive MD 5516: SPEED_FILTER_1_BW_NUMERATOR BSP blocking frequency drive MD 5514: SPEED_FILTER_1_SUPPR_FREQ, MD 5516 <= 2 * MD 5514 Manipulated variable filter 1:

BSP bandwidth numerator drive MD 5212: OUTPUT_VCTRL_FIL_1_BW_NUM BSP blocking frequency drive MD 5210: OUTPUT_VCTRL_FIL_1_SUP_FREQ, MD 5212 <= 2 * MD 5210 Manipulated variable filter 2:

BSP bandwidth numerator drive MD 5215: OUTPUT_VCTRL_FIL_2_BW_NUM

BSP blocking frequency drive MD 5213: OUTPUT_VCTRL_FIL_2_SUP_FREQ, MD 5215

<= 2 * MD 5213

Clear alarm with the RESET key in all channels. Restart part program.


1-2745


© Siemens AG 2005 All Rights Reserved