310760

Parameters:

Definitions:


Reactions:


Remedy:


Program Continuation:


Axis %1 drive %2 bandwidth denominator greater than double natural frequency

%1 = NC axis number %2 = Drive number

The bandwidth denominator of a speed or manipulated variable setpoint filter is greater than twice the natural frequency.

This error message is only issued for the general bandstop filter if:

Speed filter 1:

MD 5516 > 0.0 or MD 5520 <> 100.0

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

The bandwidth denominator of a speed or manipulated variable setpoint filter must be less than twice the natural frequency.

Speed filter 1:

BSP bandwidth drive MD 5515: SPEED_FILTER_1_BANDWIDTH

BSP blocking frequency drive MD 5514: SPEED_FILTER_1_SUPPR_FREQ

BSP natural frequency drive MD 5520: SPEED_FILTER_1_BS_FREQ, MD5515 <= 2 *

MD 5514 * 0.01 * MD 5520

Clear alarm with the RESET key in all channels. Restart part program.


© Siemens AG 2005 All Rights Reserved


1-2746