310774

Axis %1 drive %2 zero area and knee area of valve characteristic overlap

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

Reactions:

The zero area and the knee area of the valve characteristic overlap.

-    NC not ready.

-    The NC switches to follow-up mode.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

-    Channel not ready.

The zero area and the knee area overlap if:

Positive quadrant: (MD 5481 + MD 5482) > (MD 5465 - 5466)

Negative quadrant: (MD 5484 + MD 5482) > (MD 5468 - 5466)

Enter a valid combination in the above drive MD.

Program Continuation:

Clear alarm with the RESET key in all channels. Restart part program.

© Siemens AG 2005 All Rights Reserved

1-2754