Axis %1 drive %2 multiturn SSI motor measuring system invalid

Parameters:

%1 = NC axis number

%2 = Drive number

Definitions:

The configuration of a linear SSI motor measuring system is incorrect: A linear measuring system cannot have any multiturn information.

Reactions:

-    Mode group not ready.

-    Channel not ready.

-    NC Start disable in this channel.

Remedy:

-    Interface signals are set.

-    Alarm display.

-    NC Stop on alarm.

Set MD 5021 $MD ENC ABS TURN MOTOR (number of representable revolutions) to 0.

Program Continuation:

Switch control OFF - ON.

© Siemens AG 2005 All Rights Reserved