Profibus DP: no output slot available for base address %1 (size %2)
%1 = Logical base address of the requested area %2 = Size of the area in bytes
An incorrect logical base address was specified for a digital or analog input. Either no slot has been configured for this base address or the requested area extends beyond the end of the slot.
For length =1 it is a digital output,
For length =2 it is an analog output.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Enter correct base addresses in the machine data:
For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text and contact the control system manufacturer.
Switch control OFF - ON.