Nastavení sondy TT130-Heidenhain TNC530
Sonda TT130 pro měření nástroje
MP 6500 : %000000001100001
MP 6502 : 0
;————————————————————–
;MP6505 Probing direction for tool measurement
;Input:
;0 = Positive probing direction of the angle reference axis (0?
;1 = Positive probing direction in the 90?axis
;2 = Negative probing direction of the angle reference axis (0?
;3 = Negative probing direction in the 90?axis
MP 6505.0 : 0 ;Traverse range 1
MP 6505.1 : 0 ;Traverse range 2
MP 6505.2 : 0 ;Traverse range 3
;————————————————————–
;MP6507 Calculation of the probing feed rate
;Input:
; 0 = Calculation of the probing feed rate with constant tolerance
; 1 = Calculation of the probing feed rate with variable tolerance
; 2 = Constant probing feed rate
MP 6507 : 2
MP 6508 : 0
MP 6509 : 0
;————————————————————–
;MP6510 Max. permissible measuring error for tool measurement
;with rotating tool
;Input: 0.002 to 0.999 [mm]
MP 6510.0 : 0.005 ;First measuring error
MP 6510.1 : 0.01 ;Second measuring error
;————————————————————–
;MP6520 Probing feed rate for tool measurement with
;non-rotating tool
;Input: 1 to 10 000 [mm/min]
MP 6520 : 500
;————————————————————–
;MP6530 Distance from the tool end to the top of the probe contact
;during tool radius measurement
;Input: 0.001 to 99.9999 [mm]
MP 6530.0 : 5 ;Traverse range 1
MP 6530.1 : 5 ;Traverse range 2
MP 6530.2 : 5 ;Traverse range 3
;————————————————————–
;MP6531 Diameter or edge length of the probe contact
;Input: 0.001 to 99 999.9999 [mm]
MP 6531.0 : 40 ;Traverse range 1
MP 6531.1 : 40 ;Traverse range 2
MP 6531.2 : 40 ;Traverse range 3
;————————————————————–
;MP6540 Safety zone around the probe contact for pre-positioning
;Input: 0.001 to 99 999.9999 [mm]
MP 6540.0 : 10 ;Tool-axis direction
MP 6540.1 : 10 ;Machining plane
;————————————————————–
;MP6550 Rapid traverse in probing cycle
;Input: 10 to 1 000 000 [mm/min]
MP 6550 : 5000
;————————————————————–
;MP6560 M function for spindle orientation during
;individual tooth measurement
;Input: -1 to 999
; -1 = Orientation by NC
; 0 = Function inactive
MP 6560 : -1
;————————————————————–
;MP6562 M function bevor or after tool measurement cycle
;Input: -1 bis 999 [M function number]
; -1 = Function inactive
MP 6562.0 : -1 ;bevor cycle start
MP 6562.1 : -1 ;after cycle end
;————————————————————–
;MP6570 Maximum permissible surface cutting speed of
;the tool tooth
;Input: 1.0000 to 120.0000 [m/min]
MP 6570 : 50
;————————————————————–
;MP6572 Maximum permissible speed for tool measurement
;Input: 0 to 1000 rpm
; 0 = 1000 rpm
MP 6572 : 0
;————————————————————–
;MP6580 Coordinates of the probe contact center with respect to
;the machine datum (traverse range 1)
;Input: -99 999.9999 to +99 999.9999 [mm]
MP 6580.0 : -385.540 ;X poloha sondy (reference)
MP 6580.1 : 1304.9 ;Y
MP 6580.2 : -850.5 ;Z
;————————————————————–
;MP6581 Coordinates of the probe contact center with respect to
;the machine datum (traverse range 2)
;Input: -99 999.9999 to +99 999.9999 [mm]
MP 6581.0 : +0 ;X position of probe contact (reference)
MP 6581.1 : +0 ;Y
MP 6581.2 : +0 ;Z
;————————————————————–
;MP6582 Coordinates of the probe contact center with respect to
;the machine datum (traverse range 3)
;Input: -99 999.9999 to +99 999.9999 [mm]
MP 6582.0 : +0 ;X position of probe contact (reference)
MP 6582.1 : +0 ;Y
MP 6582.2 : +0 ;Z
Pozor! Při vlastním měření se nástroj točí !!!
Vložit do vřetena kalibrační nástroj ,zapsát data do tabulky nástrojů a spustit kalibrační cyklus.
TOOL CALL 1 Z
TCH PROBE 480 TT KALIBROVANI
Q260=100 ;BEZPECNA VYSKA
Poté můžeme měřit pomocí cyklů:
TCH PROBE 481;délka
TCH PROBE 482;radius
TCH PROBE 483;radius a délka,pozor prvně měří radius
Q340=0;zapisuje do L a R v tabulce nástrojů
Q340=1,zapisuje do DL a DR v tabulce nástrojů.
Před měřením nutno zadat přibližnou délku a polomer do tabulky nástrojů.